AC SPD

Type 1 AC Surge Protective Device 4P 385V – UH-AG-SP01

Model UH-AG-SP01

UH-AG-SP01 is a 4-pole Type 1 AC surge protective device designed to limit transient overvoltages and divert lightning impulse currents in low-voltage AC distribution systems. The 385V AC platform provides a 25kA Iimp rating with a 10/350 μs waveform and a voltage protection level of ≤2.5kV.

  • Type 1 Protection
  • 25kA Iimp
  • 4P / 385V AC
SPD Type Type 1 / T1
Maximum Continuous Operating Voltage Uc 385V AC
Impulse Discharge Current Iimp 25kA
Iimp Waveform 10/350 μs
Voltage Protection Level Up ≤2.5kV
Pole Configuration 4P

UH-AG-SP01 provides surge protection only and does not replace the circuit breaker or fuse required for overload and short-circuit protection.

Overview

Product Overview

UH-AG-SP01 is a Type 1 surge protective device designed for the incoming side of low-voltage AC distribution systems where lightning impulse current and severe transient overvoltage protection are required. The 4-pole unit provides terminals for three phase conductors and neutral, together with a protective-earth connection.

The product is specified with a maximum continuous operating voltage Uc of 385V AC, an impulse discharge current Iimp of 25kA using the 10/350 μs waveform, and a voltage protection level Up of ≤2.5kV. Its modular DIN-rail construction allows the SPD to be integrated into distribution boards and other AC protection assemblies.

Features

Key Product Features

Type 1 Protection
25kA Iimp
4P / 385V AC

Type 1 Lightning Protection

UH-AG-SP01 is designed as a Type 1 SPD for installations where lightning impulse current may enter the low-voltage AC distribution system.

25kA Lightning Impulse Current

The SPD is marked with an Iimp rating of 25kA using the 10/350 μs lightning-current waveform.

385V AC Continuous Operating Voltage

A maximum continuous operating voltage Uc of 385V AC supports use in appropriate three-phase low-voltage AC distribution systems.

≤2.5kV Voltage Protection Level

The marked voltage protection level Up is ≤2.5kV, indicating the residual protection level specified for the SPD during surge operation.

Four-Pole Construction

The 4P housing provides L1, L2, L3 and N connections together with a PE connection for three-phase four-wire protection arrangements.

Modular DIN-Rail Design

The compact modular construction is designed for installation inside AC distribution boards and related electrical protection equipment.

Technical Data

Technical Specifications

Review the complete technical parameters for product selection and project verification.

Electrical Characteristics

Parameter Value
SPD Type Type 1 / T1
Maximum Continuous Operating Voltage Uc 385V AC
Impulse Discharge Current Iimp 25kA
Iimp Waveform 10/350 μs
Voltage Protection Level Up ≤2.5kV
Pole Configuration 4P
Conductors L1 / L2 / L3 / N + PE
Application AC Low-Voltage Surge Protection

Mechanical Characteristics

Parameter Value
Mounting DIN Rail
Construction Modular / Pluggable SPD
Housing Insulated Modular Housing
Pole Count 4P

Applications

Where This Product Is Used

Commercial Buildings

Commercial Buildings

Protection, switching, distribution and enclosure components for commercial and light-industrial electrical installations.

Residential Electrical

Residential Electrical

Protection, switching and backup-power components for residential distribution boards and low-voltage electrical systems.

UH-AG-SP01 is intended for AC main distribution boards, building incoming distribution panels and other low-voltage installations requiring Type 1 surge protection against lightning-related transient overvoltages. SPD selection must consider the system voltage, earthing arrangement, lightning protection concept and required coordination with downstream surge protection devices.

Installation

Installation Guidance

1. Verify that the AC distribution system voltage, earthing arrangement and required SPD protection mode are compatible with UH-AG-SP01 before installation.

2. Fully isolate the AC supply before installing or servicing the surge protective device.

3. Mount UH-AG-SP01 securely on the specified DIN rail inside the electrical distribution enclosure.

4. Connect the phase conductors and neutral to the terminals marked L1, L2, L3 and N, and connect the protective-earth conductor to the PE terminal according to the approved wiring diagram.

5. Keep SPD connection conductors as short and direct as practical to minimize additional inductive voltage during surge discharge.

6. Install and coordinate the required upstream short-circuit / overcurrent protective device according to the final SPD technical documentation and distribution-system design.

7. Verify all conductor connections, polarity / terminal identification and protective-earth continuity before energizing the AC distribution system.

8. The SPD provides transient overvoltage protection only. It does not replace circuit breakers or fuses required for overload and short-circuit protection.

Important Notes

UH-AG-SP01 provides surge protection only and does not replace the circuit breaker or fuse required for overload and short-circuit protection.

FAQ

Frequently Asked Questions

What does a Type 1 surge protective device protect against?

A Type 1 SPD is designed to divert lightning impulse current and limit transient overvoltage entering the low-voltage AC distribution system.

What does 25kA Iimp mean?

UH-AG-SP01 is marked with an impulse discharge current Iimp of 25kA using the 10/350 μs lightning-current waveform used for Type 1 SPD testing.

What does Uc 385V mean?

Uc is the maximum continuous operating voltage that may be continuously applied to the SPD under specified conditions. It should not be confused with the nominal voltage of the complete AC distribution system.

Need More Information About This Product?

Contact UHCCY for technical details, product selection, samples, pricing, and OEM/ODM requirements.

Get A Quote